This is a DIN-rail mount, suitable for standard household distribution boards. 6. Troubleshooting
Understanding your device's physical limits prevents premature hardware failure and ensures overall electrical safety. 230VAC, 50/60Hz Max Loading Power: Adjustable from 1A to 63A (Default: 63A) Power Consumption: < 2W Mechanical & Electrical Life: 100,000 cycles Mounting: Standard 35mm DIN rail Step-by-Step Programming Guide TOMZN TOVPD1-60-EC Go to product viewer dialog for this item.
: Tap the Set button briefly to save the current step and jump directly to the next configuration metric. tomzn tovpd160ec manual better
The original TOMZN TOVPD160EC manual is a technical datasheet. This guide is the —the one that explains why as well as how .
Proper wiring is critical to avoid destroying the internal circuitry. The device features clearly marked terminals on the top and bottom of the casing. This is a DIN-rail mount, suitable for standard
[ SET ] --> Press to cycle through codes (A1 to A14) [ UP ] --> Increase value / Query last fault code [ DOWN ] --> Decrease value / Long press 12s for Reset Step 3: Complete Parameter Menu Table Parameter Function Adjustable Range Factory Default Recommended Setting Power-On Delay Time 1s – 500s 10s (30s for refrigeration) A2 Over-Voltage Cut-off Value 230V – 300V (or OFF) A3 Over-Voltage Recovery Value 225V – 295V A4 Over-Voltage Action Time 0.1s – 30s A5 Over-Voltage Recovery Delay 1s – 500s A6 Under-Voltage Cut-off Value 140V – 210V (or OFF) A7 Under-Voltage Recovery Value 145V – 215V A8 Under-Voltage Action Time 0.1s – 30s A9 Under-Voltage Recovery Delay 1s – 500s A10 Over-Current Limit Range 1A – 63A Match your main breaker A11 Over-Current Action Time 0.1s – 30s 1.0s (allows motor inrush) A12 Over-Current Recovery Delay 1s – 500s A13 Voltage Calibration Adjust -10% to +10% Use a trusted multimeter A14 Current Limit Retry Count 1 – 20 times (or OFF) OFF (Manual intervention safe) Wiring & Installation Instructions
If you get lost in the settings, most TOVPD1 devices support factory reset by . 230VAC, 50/60Hz Max Loading Power: Adjustable from 1A
Press "SET" again to move to the next parameter: Over-voltage (V>) Under-voltage (V<) Over-current (A>) Reconnection Time (Time) Voltage Calibration (U)
Because the manual doesn't cover these scenarios, here is the "Better" diagnostic guide.
If you need help resolving a specific issue with your unit, let me know your current , your configured limits , or any fault codes on your screen, and I can help you dial in the ideal settings. Share public link